MECHANICAL VENTILATION HOLD NR 2 AFT

Deck Forward SOLARIS May 28, 2026 14:00 anonymous
Completed
Inspection

Equipment Type

Deck Machinery

Location

Deck Forward

AI Analysis Results

Overall Condition

Poor

Risk: high

Equipment Identified

Ventilation system components (grilles, ducts), possibly part of the engine room or mechanical room.

Analysis Summary

The visible ventilation components show significant signs of corrosion and rust, indicating a lack of proper maintenance and potential failure points. The deterioration may impair functionality, leading to inadequate ventilation which can jeopardize safety and operational efficiency.

Defects Found (2)

Corrosion
severe

Heavy rust and corrosion observed on the ventilation ductwork, suggesting exposure to moisture and lack of protective coating.

Seal degradation
moderate

Seals and caulking at joints are damaged, allowing possible ingress of contaminants and moisture.

Recommendations

1

Perform thorough cleaning and rust removal on the corroded areas.

Priority: highTimeframe: immediate
2

Apply appropriate corrosion-resistant coatings to all affected surfaces.

Priority: highTimeframe: within 1 week
3

Inspect and replace deteriorated seals to ensure airtight conditions.

Priority: mediumTimeframe: within 2 weeks
4

Conduct a full inspection of the entire ventilation system to assess overall health and identify any further maintenance needs.

Priority: urgentTimeframe: within 48 hours

SMS / Compliance References

ISM Code Section 10 - Maintenance of the ship and equipment
MARPOL Annex I - Prevention of Pollution by Oil (requires maintenance and repair to prevent leaks)
MLC 2006 Regulation 4.3 - Health and safety protection (ensuring a safe working environment)